4. Detach the timing belt from the carriage unit using round nose pliers.
Be careful not to damage it.
5. Lift portion A of the carriage guide shaft ground plate to remove it from the notch in the carriage
motor frame, and slide
portion B of the plate).
the plate so that it can be removed from the
Carriaga Guide
Shaft Ground.
frame (through the cutout at
18
A/
Plata
74
“orFrame\
+<’
%.*
Fig. 4-21. Removal of Carriage Guide Shaft Ground Plate
6. Place the printer mechanism face up. Turn the left carriage guide shaft lever fully counterclockwise
and pull it out through cutout A. Then
turn
the right carriage guide shaft lever fully clockwise, and
pull it out the same way as the left lever.
Frame
A
Carriage Guide
Shaft Laver (Left)
_
h%
)Q
.
I
\
(Viewed from Left Side)
Fig. 4-22. Removal of Carriage Guide Shaft
4-14