Epson Powerspan Dokumentacja Strona 1

Przeglądaj online lub pobierz Dokumentacja dla Części komputerowe Epson Powerspan. Epson Powerspan Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 280
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - Reference Guide

Reference GuideAgilent Technologies8719ET/20ET/22ET8719ES/20ES/22ESNetwork AnalyzersPart Number 08720-90393Printed in USAFebruary 2001Supersedes July

Strona 2

1-28719/20/22ES Specifications and CharacteristicsDefinitionsDefinitionsAll specifications and characteristics apply over a 23 °C ±3 °C range (unless othe

Strona 3 - Safety Notes

3-6Front/Rear PanelAnalyzer Display2. Stimulus Stop Value. This value could be any one of the following:• The stop frequency of the source in frequenc

Strona 4 - How to Use This Guide

3-7Front/Rear PanelAnalyzer Displayext Waiting for an external trigger.Ofs (ES) Frequency offset mode is on. (See the “Making MixerMeasurements” chapt

Strona 5 - Documentation Map

3-8Front/Rear PanelAnalyzer Display4. Active Entry Area. This displays the active function and its currentvalue.5. Message Area. This displays prompts

Strona 6 - Contents

3-9Front/Rear PanelRear Panel Features and ConnectorsRear Panel Features and ConnectorsFigure 3-4 8719/20/22ET/ES Rear PanelFigure 3-4 illustrates the

Strona 7

3-10Front/Rear PanelRear Panel Features and Connectors7. Fan. This fan provides forced-air cooling for the analyzer.8. 10 MHZ PRECISION REFERENCE OUTP

Strona 8

4-14 Menu Maps

Strona 9 - 1 8719/20/22ES

4-2Menu MapsMenu MapsMenu MapsThis chapter contains menus maps for the hardkeys listed below. The figure number ofthese menu maps is listed next to the

Strona 10 - Definitions

4-3Menu MapsMenu MapsFigure 4-2 Menu Map for Copy

Strona 11

4-4Menu MapsMenu MapsFigure 4-3 Menu Map for Display

Strona 12

4-5Menu MapsMenu MapsFigure 4-4 Menu Map for Format

Strona 13

1-38719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Corrected System Performance (8719/20ES)Thespecificationsinthi

Strona 14

4-6Menu MapsMenu MapsFigure 4-5 Menu Map for Local

Strona 15

4-7Menu MapsMenu MapsFigure 4-6 Menu Map for Marker, Marker Fctn, and Marker Search

Strona 16

4-8Menu MapsMenu MapsFigure 4-7 Menu Map for Meas (ET Models Only)REFLECTIONTRANSMISSNANALOG INAux InputCONVERSION[]INPUTPORTSRESOLUTION[LOW]AUX OUTon

Strona 17

4-9Menu MapsMenu MapsFigure 4-8 Menu Map for Meas (ES Models Only)

Strona 18

4-10Menu MapsMenu MapsFigure 4-9 Menu Map for Power and Sweep Setup (ET Only)

Strona 19

4-11Menu MapsMenu MapsFigure 4-10 Menu Map for Power and Sweep Setup (ES Only)

Strona 20

4-12Menu MapsMenu MapsFigure 4-11 Menu Map for Preset

Strona 21

4-13Menu MapsMenu MapsFigure 4-12 Menu Map for Save/Recall

Strona 22

4-14Menu MapsMenu MapsFigure 4-13 Menu Map for Scale Ref

Strona 23

kl510etsSELECTLETTERSPACEBACKSPACEERASETITLEDONELabel KitMenuCAL Z0:LINE Z0SYSTEM Z0SET REF:THRUREFLECTRETURNTRL OptionMenuUSE SENSORA / BCAL FACTORSE

Strona 24

1-48719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table1-2System Dynamic Range, All Device Connector Types8722E

Strona 25

kl509etsMenu Map For Cal (8719/20/22ES only)CalECalMenuMODULEA bS111-PORTS221-PORTFULL2-PORTS11/S21ENH. RESP.S22/S12ENH. RESP.CONFIGURE[MODULE A]R

Strona 26

CONTINUESEQUENCEDOSEQUENCEGOSUBSEQUENCENEW SEQ/MODIFY SEQDONE SEQMODIFYTTL I/OSPECIALFUNCTIONSMORESEQUENCE XSEQ XPAUSE TOSELECTRETURNSEQUENCE 1SEQ

Strona 27

Menu Map for System (8719/20/22ET only)SystemOnly appears on instruments* equipped with Option 010. Service menu key descriptions are

Strona 28

SystemTIME STAMPON offROUNDSECONDSSETMINUTESSETHOURSETDAYSETMONTHSETYEARRETURNSet ClockMenuNETWORKANALYZERTUNEDRECEIVEREXT R CHANon OFFFREQS OFFSMEN

Strona 29

5-15 Hardkey/Softkey Reference

Strona 30

5-2Hardkey/Softkey ReferenceKey ReferenceKey ReferenceThis chapter contains information on the following topics:• softkey and front-panel functions in

Strona 31

5-3Hardkey/Softkey ReferenceWhere to Look for More InformationWhere to Look for More InformationAdditional information about many of the topics discus

Strona 32 - Instrument Specifications

5-4Hardkey/Softkey ReferenceAnalyzer FunctionsAnalyzer FunctionsThis section contains an alphabetical listing of softkey and front-panel functions, an

Strona 33

5-5Hardkey/Softkey ReferenceAnalyzer Functionsgoes to the delta marker menu, which is used to read thedifference in values between the active marker a

Strona 34 - Test Port Output

5-6Hardkey/Softkey ReferenceAnalyzer Functionsselects the 85056K cal kit.selects the 2.92 mm cal kit model.selects the 85033C cal kit.selects the 8505

Strona 35 - Table 1-24 Test Port Output

1-58719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-3 3.5-mm Device Connector TypeNetwork Analyzer: 8719E

Strona 36 - Table 1-25 Test Port Output

5-7Hardkey/Softkey ReferenceAnalyzer Functions1) displays the edit segment menu and adds a newsegment to the end of the list. The new segment is initi

Strona 37 - Table 1-26 Test Port Output

5-8Hardkey/Softkey ReferenceAnalyzer Functionsdefines the standard type to be a load, but with anarbitrary impedance (different from system Z0).sets th

Strona 38 - Table 1-27 Test Port Output

5-9Hardkey/Softkey ReferenceAnalyzer Functionsaveraging starts at 1 and averages each new sweep intothe trace until it reaches the specified averaging

Strona 39 - Table 1-28 Test Port Output

5-10Hardkey/Softkey ReferenceAnalyzer Functionsadjusts the brightness of the color being modified. Refer tothe section on adjusting the display color i

Strona 40 - Table 1-29 Test Port Output

5-11Hardkey/Softkey ReferenceAnalyzer Functionskey leads to a series of menus to perform measurementcalibrations for vector error correction (accuracy

Strona 41 - Test Port Input

5-12Hardkey/Softkey ReferenceAnalyzer Functions———this default selection establishes the TRL/LRMLINE/MATCH standard as the characteristic impedance.al

Strona 42 - Table 1-31 Test Port Input

5-13Hardkey/Softkey ReferenceAnalyzer Functionsselects channel 3 data trace and limit line for display colormodification.selects channel 3 memory trace

Strona 43 - Table 1-33 Test Port Input

5-14Hardkey/Softkey ReferenceAnalyzer Functionsconfigures multiple-channel displays so that the auxiliarychannels are adjacent to or beneath the primar

Strona 44 - Table 1-34 Test Port Input

5-15Hardkey/Softkey ReferenceAnalyzer Functionsis displayed during ECal dual module operation andduring manual thru operation as a pause in the proces

Strona 45

5-16Hardkey/Softkey ReferenceAnalyzer Functionsthis math function ratios channels 1 and 2, and puts theresults in the channel 2 data array. Both chann

Strona 46 - Table 1-35 Test Port Input

1-68719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-4 3.5-mm Device Connector TypeNetwork Analyzer: 8719E

Strona 47

5-17Hardkey/Softkey ReferenceAnalyzer Functionsresets the plotting parameters to their default values.resets the printing parameters to their default

Strona 48 - General Information

5-18Hardkey/Softkey ReferenceAnalyzer Functionslets you specify the number of directory files to beinitialized on a disk. This is particularly useful w

Strona 49

5-19Hardkey/Softkey ReferenceAnalyzer Functions jumps to a softkey position, not to aspecific sequence title. Whatever sequence is in theselected softk

Strona 50

5-20Hardkey/Softkey ReferenceAnalyzer FunctionsPower meter calibration occurs on each sweep. Eachmeasurement point is measured by the power meter,whic

Strona 51

5-21Hardkey/Softkey ReferenceAnalyzer Functionssets the TTL output on TEST SEQ BNC or the test setinterconnect to normally high with a 10 microseconds

Strona 52

5-22Hardkey/Softkey ReferenceAnalyzer Functionsadds electrical delay to the input B reference plane for anyB input measurements including S-parameters

Strona 53

5-23Hardkey/Softkey ReferenceAnalyzer Functionschanges the stimulus value of the fixed marker. Fixedmarker stimulus values can be different for the two

Strona 54 - Speed Parameters

5-24Hardkey/Softkey ReferenceAnalyzer Functionsclears all internal save registers and associated cal dataand memory traces.causes subsequent disk init

Strona 55 - Total Time

5-25Hardkey/Softkey ReferenceAnalyzer Functionsdisplays the complex admittance values of the activemarker in rectangular form. The active marker value

Strona 56

5-26Hardkey/Softkey ReferenceAnalyzer Functionssets the format of the graphic file when is selected. The only graphicselection currently available is t

Strona 57

1-78719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-5 3.5-mm Device Connector TypeNetwork Analyzer: 8719E

Strona 58 - 2 8719/20/22ET

5-27Hardkey/Softkey ReferenceAnalyzer Functionsprompts the user to select a destination sequence position(SEQUENCE 1 through 6). When the value of the

Strona 59

5-28Hardkey/Softkey ReferenceAnalyzer Functionsterminates the cal kit modification process, after allstandards are defined and all classes are specified.

Strona 60

5-29Hardkey/Softkey ReferenceAnalyzer Functionsturns limit testing on or off. When limit testing is on, thedata is compared with the defined limits at

Strona 61

5-30Hardkey/Softkey ReferenceAnalyzer Functionsprovides a tabular listing of all the measured data pointsand their current values, together with limit

Strona 62

5-31Hardkey/Softkey ReferenceAnalyzer Functionsleads to the LO menu. Allows you to configure the externalsource for frequency offset.shows the GPIB add

Strona 63

5-32Hardkey/Softkey ReferenceAnalyzer Functionsdisplays the current value of the loop counter and allowsyou to change the value of the loop counter. E

Strona 64

5-33Hardkey/Softkey ReferenceAnalyzer Functionsallows the insertion of a different thru during the ECalcorrection routine. When turned ON, the routine

Strona 65

5-34Hardkey/Softkey ReferenceAnalyzer Functionsadjusts the electrical delay to balance the phase of theDUT. This is performed automatically, regardles

Strona 66

5-35Hardkey/Softkey ReferenceAnalyzer Functionsturns on marker 2 and makes it the active marker. Ifanother marker is present, that marker becomes inac

Strona 67

5-36Hardkey/Softkey ReferenceAnalyzer Functionsis used to:1) define the highest frequency at which a calibration kitstandard can be used during measure

Strona 68

1-88719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-6 3.5-mm Device Connector TypeNetwork Analyzer: 8719E

Strona 69

5-37Hardkey/Softkey ReferenceAnalyzer Functionsis used to:1) define the lowest frequency at which a calibration kitstandard can be used during measurem

Strona 70 - Table 2-8 Test Port Output

5-38Hardkey/Softkey ReferenceAnalyzer Functionsselects the module to be used in the ECal operation. Selectthe module according to frequency range and

Strona 71 - Table 2-9 Test Port Output

5-39Hardkey/Softkey ReferenceAnalyzer FunctionsThe possible values that can be entered for number ofpoints are 3, 11, 26, 51, 101, 201, 401,801, and 1

Strona 72 - Table 2-10 Test Port Output

5-40Hardkey/Softkey ReferenceAnalyzer Functionsleads to the series of menus used to perform ahigh-accuracy two-port calibration without anS-parameter

Strona 73 - Table 2-11 Test Port Output

5-41Hardkey/Softkey ReferenceAnalyzer Functionswhile creating a sequence, this softkey inserts a commandto jump to another sequence if the single inpu

Strona 74 - Table 2-12 Test Port Output

5-42Hardkey/Softkey ReferenceAnalyzer Functionsadds or subtracts a phase offset that is constant withfrequency (rather than linear). This is independe

Strona 75

5-43Hardkey/Softkey ReferenceAnalyzer Functionsconfigures the analyzer for a plotter that has a serial(RS-232) interface.selects a pen plotter such as

Strona 76 - Table 2-15 Test Port Input

5-44Hardkey/Softkey ReferenceAnalyzer FunctionsThis feature may be used to compensate for attenuationnon-linearities in either a directional coupler o

Strona 77 - Table 2-16 Test Port Input

5-45Hardkey/Softkey ReferenceAnalyzer Functionswhen displaying list values, prints the entire list inmonochrome. When displaying operating parameters,

Strona 78

5-46Hardkey/Softkey ReferenceAnalyzer Functionsturns on or off power loss correction. Power loss correctionshould be used when the power output is mea

Strona 79 - Table 2-17 Test Port Input

1-98719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-7 3.5-mm Device Connector TypeNetwork Analyzer: 8719E

Strona 80

5-47Hardkey/Softkey ReferenceAnalyzer Functionsselects whether sampler and attenuator offsets are ON orOFF. By selecting raw offsets OFF, a full two p

Strona 81 - Table 2-18 Test Port Input

5-48Hardkey/Softkey ReferenceAnalyzer Functionsrecalls the previously saved modified version of the colorset. This key appears only when a color set ha

Strona 82

5-49Hardkey/Softkey ReferenceAnalyzer Functionsdefines the measurement as S22, the complex reflectioncoefficient (magnitude and phase) of the test device

Strona 83 - Table 2-19 Test Port Input

5-50Hardkey/Softkey ReferenceAnalyzer Functions• When in the response and isolation menu, leads to the menus used toperform a response and isolation m

Strona 84

5-51Hardkey/Softkey ReferenceAnalyzer Functionsis used to enter the standard numbers for the reversetransmission (thru) calibration. (For default kits

Strona 85

5-52Hardkey/Softkey ReferenceAnalyzer Functionsdisplays the ripple value of the selected frequency band.The ripple value can be displayed in two ways

Strona 86

5-53Hardkey/Softkey ReferenceAnalyzer Functionsis used to enter the standard numbers for the second classrequired for an S111-port calibration. (For d

Strona 87

5-54Hardkey/Softkey ReferenceAnalyzer Functionsstores the user-modified or user-defined kit into memory,after it has been modified.selects ASCII format f

Strona 88

5-55Hardkey/Softkey ReferenceAnalyzer Functionsturns off the marker search function.searches for the user-specified target point on the trace.specifies

Strona 89

5-56Hardkey/Softkey ReferenceAnalyzer Functionsprompts the analyzer to run a series of tests to determinea problem.accesses a series of sequencing men

Strona 90

1-108719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-8 7-mm Device Connector TypeNetwork Analyzer: 8719ES

Strona 91

5-57Hardkey/Softkey ReferenceAnalyzer Functionsallows you to set the month in the analyzer's internalclock.sets the measurement reference plane t

Strona 92

5-58Hardkey/Softkey ReferenceAnalyzer Functionssets the limits at a single stimulus point. If limit lines areon, the upper limit value of a single poi

Strona 93

5-59Hardkey/Softkey ReferenceAnalyzer Functionslets you change the value of the smoothing aperture as apercent of the span. When smoothing aperture is

Strona 94

5-60Hardkey/Softkey ReferenceAnalyzer Functionsselects whether spur avoidance is ON or OFF. Selectingspur avoidance OFF, along with selecting raw offs

Strona 95 - 3 Front/Rear Panel

5-61Hardkey/Softkey ReferenceAnalyzer Functionssets the starting stimulus value of a segment, using entryblock controls. The ending stimulus value of

Strona 96 - Front Panel Features

5-62Hardkey/Softkey ReferenceAnalyzer FunctionsThe system controller mode can be used withoutknowledge of GPIB programming. However, the GPIBaddress m

Strona 97

5-63Hardkey/Softkey ReferenceAnalyzer Functionsis used to specify the (arbitrary) impedance of thestandard, in Ωs.is used to set configurations before

Strona 98

5-64Hardkey/Softkey ReferenceAnalyzer Functionspresents the title menu in the softkey labels area and thecharacter set in the active entry area. These

Strona 99 - Analyzer Display

5-65Hardkey/Softkey ReferenceAnalyzer Functionsoutputs a title string to any device with an GPIB addressthat matches the address set with the analyzer

Strona 100

5-66Hardkey/Softkey ReferenceAnalyzer Functionsleads to the transmission menu.presents the trigger menu, which is used to select the typeand number of

Strona 101 - , the IF frequency is not

1-118719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-9 7-mm Device Connector TypeNetwork Analyzer: 8719ES

Strona 102

5-67Hardkey/Softkey ReferenceAnalyzer Functions(Option 010 only) remembers a specified window pulsewidth (or step rise time) different from the standar

Strona 103 - Front/Rear Panel

5-68Hardkey/Softkey ReferenceAnalyzer Functionsspecifies the number of the disk volume to be accessed. Ingeneral, all 3.5 inch floppy disks are consider

Strona 104 - MEASURE RESTART

5-69Hardkey/Softkey ReferenceAnalyzer FunctionsIf a delta marker or fixed marker is on, it is used as thereference point from which the bandwidth ampli

Strona 105 - 4 Menu Maps

6-16 Error Messages

Strona 106 - Menu Maps

6-2Error MessagesError MessagesError MessagesThis chapter contains the following information to help you interpret any error messagesthat may be displ

Strona 107 - Figure 4-2 Menu Map for Copy

6-3Error MessagesError Messages in Alphabetical OrderError Messages in Alphabetical OrderABORTING COPY OUTPUTInformationMessageThis message is display

Strona 108

6-4Error MessagesError Messages in Alphabetical OrderARGUMENT OUT OF RANGEError Number206The argument for a programming command is out of the specified

Strona 109

6-5Error MessagesError Messages in Alphabetical OrderBATTERY FAILED. STATE MEMORY CLEAREDError Number183The battery protection of the non-volatile CMO

Strona 110 - Figure 4-5 Menu Map for Local

6-6Error MessagesError Messages in Alphabetical OrderCANNOT FORMAT DOS DISKS ON THIS DRIVEError Number185You have attempted to initialize a floppy disk

Strona 111

6-7Error MessagesError Messages in Alphabetical OrderCH1 (CH2, CH3, CH4) TARGET VALUE NOT FOUNDError Number159Your target value for the marker search

Strona 112 - Meas (ET Models Only)

iiNoticeThe information contained in this document is subject to change without notice.Agilent Technologies makes no warranty of any kind with regard

Strona 113 - Meas (ES Models Only)

1-128719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-10 Type-N Device Connector TypeNetwork Analyzer: 871

Strona 114

6-8Error MessagesError Messages in Alphabetical OrderCORRECTION TURNED OFFError Number66Critical parameters in your current instrument state do not ma

Strona 115

6-9Error MessagesError Messages in Alphabetical OrderDISK IS WRITE PROTECTEDError Number48The store operation cannot write to a write-protected disk.

Strona 116

6-10Error MessagesError Messages in Alphabetical OrderECal: CHECKING ORIENTATIONInformationMessageThis message is displayed while the network analyzer

Strona 117 - Save/Recall

6-11Error MessagesError Messages in Alphabetical OrderECal: SELECT OTHER MODULEError Number221This error occurs when two ECal modules are connected. T

Strona 118 - Scale Ref

6-12Error MessagesError Messages in Alphabetical OrderFREQ OFFSET ONLY VALID IN NETWORK ANALYZER MODE (ES Option 089 Only)Error Number140You can only

Strona 119 - Response Menu

6-13Error MessagesError Messages in Alphabetical OrderGPIB COPY IN PROGRESS, ABORT WITH LOCALError Number169An GPIB copy was already in progress when

Strona 120 - Lists Menu

6-14Error MessagesError Messages in Alphabetical OrderINSUFFICIENT MEMORY, PWR MTR CAL OFFError Number154There is not enough memory space for the powe

Strona 121 - SEQUENCE X

6-15Error MessagesError Messages in Alphabetical OrderMEMORY FOR CURRENT SEQUENCE IS FULLError Number132All the memory in the sequence you are modifyi

Strona 122

6-16Error MessagesError Messages in Alphabetical OrderNO MEMORY AVAILABLE FOR INTERPOLATIONError Number123You cannot perform interpolated error correc

Strona 123

6-17Error MessagesError Messages in Alphabetical OrderOK TO ALTER CORRECTION CONSTANTS?Error Number186This message is displayed as a prompt during ope

Strona 124 - 5 Hardkey/Softkey Reference

1-138719/20/22ES Specifications and CharacteristicsCorrected System Performance (8719/20ES)Table 1-11 Type-N Device Connector TypeNetwork Analyzer: 871

Strona 125 - Key Reference

6-18Error MessagesError Messages in Alphabetical OrderOVERLOAD ON INPUT R, POWER REDUCEDError Number57You have exceeded approximately +14 dBm at one o

Strona 126 - Guide Terms and Conventions

6-19Error MessagesError Messages in Alphabetical OrderPLOTTER: not on, not connect, wrong addrsError Number26The plotter does not respond to control.

Strona 127 - Analyzer Functions

6-20Error MessagesError Messages in Alphabetical OrderPRINT ABORTEDError Number25When you press the key, the analyzer aborts output to the printer.pr

Strona 128

6-21Error MessagesError Messages in Alphabetical OrderPRINTER: power offError Number174The power to the printer at the parallel port is off.PRINTER: r

Strona 129

6-22Error MessagesError Messages in Alphabetical OrderSEGMENT #n POWER OUTSIDE RANGE LIMITInformationMessageThe selected power range does not support

Strona 130

6-23Error MessagesError Messages in Alphabetical OrderSOURCE POWER DISABLED, EDIT LIST MODE TBLInformationMessageWhen list power has been enabled and

Strona 131

6-24Error MessagesError Messages in Alphabetical OrderSYST CTRL OR PASS CTRL IN LOCAL MENUError Number36The analyzer is in talker/listener mode. In th

Strona 132

6-25Error MessagesError Messages in Alphabetical OrderVALID ONLY FOR BILATERAL DEVICESInformationMessageThis message is displayed when an enhanced refl

Strona 133

6-26Error MessagesError Messages in Numerical OrderError Messages in Numerical OrderErrorNumberError1 OPTIONAL FUNCTION; NOT INSTALLED2 INVALID KEY3 C

Strona 134

6-27Error MessagesError Messages in Numerical Order33 SYNTAX ERROR34 BLOCK INPUT ERROR35 BLOCK INPUT LENGTH ERROR36 SYST CTRL OR PASS CTRL IN LOCAL ME

Strona 135

1-148719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Corrected System Performance (8722ES)The specifications in this

Strona 136

6-28Error MessagesError Messages in Numerical Order63 CALIBRATION REQUIRED64 CURRENT PARAMETER NOT IN CAL SET65 CORRECTION AND DOMAIN RESET66 CORRECTI

Strona 137

6-29Error MessagesError Messages in Numerical Order132 MEMORY FOR CURRENT SEQUENCE IS FULL133 THIS LIST FREQ INVALID140 FREQ OFFSET ONLY VALID IN NETW

Strona 138

6-30Error MessagesError Messages in Numerical Order181 BAD FREQ FOR HARMONIC OR FREQ OFFSET182 LIST MODE OFF: INVALID WITH LO FREQ183 BATTERY FAILED.

Strona 139

6-31Error MessagesError Messages in Numerical Order212 ANALOG BUS DISABLED IN 6 KHZ IF BW213 RANGE CAUSED POWER LVL CHANGE IN LIST214 CORRECTION ON: A

Strona 140

7-17 Options and Accessories

Strona 141

7-2Options and AccessoriesUsing This ChapterUsing This ChapterThis chapter contains information on the following subjects:• “Analyzer Options Availabl

Strona 142

7-3Options and AccessoriesAnalyzer Options AvailableAnalyzer Options AvailableOption 1D5, High Stability Frequency ReferenceOption 1D5 offers ±0.05 pp

Strona 143

7-4Options and AccessoriesAnalyzer Options AvailableAdditionally, there is an external reference input that allows the external amplifier'sfreque

Strona 144

7-5Options and AccessoriesAccessories AvailableAccessories AvailableFor accessories not listed in this section, refer to the configuration guide for yo

Strona 145

7-6Options and AccessoriesAccessories Available• 85134F set, flexible: 3.5-mm to 2.4-mm, 53-cm (21-in) each.For the 8722ET/ES.Test-Port Cables: 7mm• 85

Strona 146

1-158719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-12 2.4-mm Device Connector TypeNetwork Analyzer: 8722ES

Strona 147

7-7Options and AccessoriesAccessories Available— Option 001Deletes 3.5-mm to 7-mm adapters. Recommended if the kit will not be used with the8753 netwo

Strona 148

7-8Options and AccessoriesAccessories AvailableRF electronic calibration (ECal) modules and PC softwareThis product family provides electronic calibra

Strona 149

7-9Options and AccessoriesAccessories Available— Option 00M substitutes type-N (m) to type-N (m) Microwave ECal module.— Option 001 adds a 30 kHz to 9

Strona 150

7-10Options and AccessoriesAccessories AvailableAdapters• 11904A 2.4-mm (m) to K (m) adapter• 11904B 2.4-mm (f) to K (f) adapter• 11904C 2.4-mm (m) to

Strona 151

7-11Options and AccessoriesAccessories AvailableTest Configuration AccessoriesPower MetersFor more accurate control of leveled test-port power. Require

Strona 152

7-12Options and AccessoriesAccessories AvailableKeyboard TemplateThe analyzer is designed to accept most PC-AT-compatible keyboards with a mini-DINcon

Strona 153

8-18 Preset State and Memory Allocation

Strona 154

8-2Preset State and Memory AllocationPreset StatePreset StateWhen the key is pressed, the analyzer reverts to a known state called the factorypreset

Strona 155

8-3Preset State and Memory AllocationPreset StateTable 8-1 Preset ConditionsPreset Conditions Preset ValueAnalyzer ModeAnalyzer Mode Network Analyzer

Strona 156

8-4Preset State and Memory AllocationPreset StateSource Power (8722, Opt. 007) −5 dBmStart Power (8719/20) −15.0 dBmStart Power (8719/20, Opt. 007) −1

Strona 157

1-168719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-13 2.4-mm Device Connector TypeNetwork Analyzer: 8722ES

Strona 158

8-5Preset State and Memory AllocationPreset StateConversion OffFormat Log Magnitude (all inputs)Display DataColor SelectionsSame as beforeDual Channel

Strona 159

8-6Preset State and Memory AllocationPreset StateSystem Z0 50 OhmsVelocity Factor 1Extensions OffPort 1 0 sPort 2 0 sInput A 0 sInput B 0 sChop A and

Strona 160

8-7Preset State and Memory AllocationPreset StateMarker Width Value −3 dB; OffMarker Tracking OffMarker Stimulus Offset 0 HzMarker Value Offset 0 dBMa

Strona 161

8-8Preset State and Memory AllocationPreset StateTransform Span 4 nanosecondsGating OffGate Shape NormalGate Start −500 picosecondsGate Span 500 picos

Strona 162

8-9Preset State and Memory AllocationPreset StateFormatted Data Array OffGraphics OffData Only OffDirectory SizeDefaultaSave Using BinarySelect Disk I

Strona 163

8-10Preset State and Memory AllocationPreset StateCh2/Ch4 Memory 6Ch1/Ch3 Graticule 1Ch2/Ch4 Graticule 1Ch1/Ch3 Text 7Ch2/Ch4 Text 7Ch1/Ch3 Marker 7Ch

Strona 164

8-11Preset State and Memory AllocationPreset StateTable 8-2 Preset ConditionsFormat Table Scale ReferencePosition ValueLog Magnitude (dB) 10.0 5.0 0.0

Strona 165

8-12Preset State and Memory AllocationPreset StateTable 8-4 Results of Power Loss to Non-Volatile MemoryGPIB ADDRESSES are set to the following defaul

Strona 166

8-13Preset State and Memory AllocationMemory AllocationMemory AllocationThe analyzer is capable of saving complete instrument states for later retriev

Strona 167

8-14Preset State and Memory AllocationMemory AllocationNOTE Even though calibration data is stored in non-volatile memory, if theassociated instrument

Strona 168

1-178719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-14 3.5-mm Device Connector TypeNetwork Analyzer: 8722ES

Strona 169

8-15Preset State and Memory AllocationMemory AllocationDetermining Memory RequirementsTable 8-5 shows the memory requirements of calibration arrays an

Strona 170

8-16Preset State and Memory AllocationMemory AllocationThe analyzer attempts to allocate memory at the start of a calibration. If insufficientmemory is

Strona 171

8-17Preset State and Memory AllocationMemory AllocationStoring Data to DiskYou can use the internal disk drive or connect an external disk drive for s

Strona 172

8-18Preset State and Memory AllocationMemory AllocationTable 8-6 Suffix Character DefinitionsChar 1 Definition Char 2 DefinitionI, PInstrument stateaW Fou

Strona 173

8-19Preset State and Memory AllocationMemory AllocationIf correction is on at the time of an external store, the calibration set is stored to disk.(No

Strona 174

9-19 Understanding the CITIfile DataFormat

Strona 175

9-2Understanding the CITIfile Data FormatUsing This ChapterUsing This ChapterThe descriptions and examples shown in this chapter demonstrate how CITIfil

Strona 176

9-3Understanding the CITIfile Data FormatThe CITIfile Data FormatThe CITIfile Data FormatDescription and OverviewCITIfile is a standardized data format, u

Strona 177

9-4Understanding the CITIfile Data FormatThe CITIfile Data FormatA CITIfile PackageA typical package is divided into two parts: The first part, the header

Strona 178

9-5Understanding the CITIfile Data FormatThe CITIfile Data FormatA CITIfile package may contain more than one array of data. Arrays of data start after t

Strona 179

1-188719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-15 3.5-mm Device Connector TypeNetwork Analyzer: 8722ES

Strona 180

9-6Understanding the CITIfile Data FormatThe CITIfile Data FormatNAME DATA#NA REGISTER 1VAR FREQ MAG 10DATA S[1,1] RISEG_LIST_BEGINSEG 1000000000 400000

Strona 181

9-7Understanding the CITIfile Data FormatThe CITIfile Data Format#NA DUPLICATES 0#NA ARB_SEG 1000000000 1000000000 1#NA ARB_SEG 2000000000 3000000000 3V

Strona 182

9-8Understanding the CITIfile Data FormatCITIfile KeywordsCITIfile KeywordsKeyword Explanation and ExamplesCITIFILE CITIFILE A.01.01 identifies the file as

Strona 183

9-9Understanding the CITIfile Data FormatCITIfile KeywordsSEG_LIST_BEGIN SEG_LIST_BEGIN indicates that a list of segments forthe independent variable fo

Strona 184

9-10Understanding the CITIfile Data FormatCITIfile KeywordsCONSTANT CONSTANT [name] [value] allows for the recording ofvalues which don’t change when th

Strona 185

9-11Understanding the CITIfile Data FormatUseful CalculationsUseful CalculationsThis section contains information on computing frequency points and exp

Strona 186

9-12Understanding the CITIfile Data FormatUseful CalculationsExpressing CITIfile Data in Other Data FormatsCITIfile data is represented in real and imagi

Strona 187

9-13Understanding the CITIfile Data FormatUseful CalculationsExample DataThis example shows how the following CITIfile data for a three-point trace can

Strona 188

10-110 Determining System MeasurementUncertainties

Strona 189

10-2Determining System Measurement UncertaintiesIntroductionIntroductionIn any measurement, certain measurement errors associated with the system addu

Strona 190 - --------=

1-198719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-16 3.5-mm Device Connector TypeNetwork Analyzer: 8722ES

Strona 191

10-3Determining System Measurement UncertaintiesSources of Measurement ErrorsSources of Measurement ErrorsMeasurement errors are made up of systematic

Strona 192

10-4Determining System Measurement UncertaintiesSources of Measurement ErrorsSources of Random ErrorsThe random error sources are noise, connector rep

Strona 193 - 6 Error Messages

10-5Determining System Measurement UncertaintiesDetermining Expected System PerformanceDetermining Expected System PerformanceImproper connection tech

Strona 194 - Error Messages

10-6Determining System Measurement UncertaintiesDetermining Cable Stability Terms (CR1, CR2, CTM1, CTM2, CTP1, CTP2)Determining Cable Stability Terms(

Strona 195

10-7Determining System Measurement UncertaintiesDetermining Cable Stability Terms (CR1, CR2, CTM1, CTM2, CTP1, CTP2)Figure 10-2 Cable Stability with a

Strona 196

10-8Determining System Measurement UncertaintiesMeasurement Uncertainty EquationsMeasurement Uncertainty EquationsAny measurement result is the vector

Strona 197

10-9Determining System Measurement UncertaintiesMeasurement Uncertainty EquationsForward Transmission UncertaintyEquation 10-3. Forward Transmission M

Strona 198

10-10Determining System Measurement UncertaintiesMeasurement Uncertainty EquationsReverse Reflection UncertaintyEquation 10-5. Reverse Reflection Magnit

Strona 199

10-11Determining System Measurement UncertaintiesMeasurement Uncertainty EquationsReverse Transmission UncertaintyEquation 10-7. Reverse Transmission

Strona 200

IndexIndexAaccessories available, 7-5keyboard template, 7-12measurement accessories, 7-5adapters, 7-10allocation, memory, 8-13Analyzerpanelsfront, 3-2

Strona 201

1-208719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-17 Type-N Device Connector TypeNetwork Analyzer: 8722ES

Strona 202

2 IndexIndexPpads, minimum loss, 7-10PC software, 7-8performance, determining, 10-5power meters, 7-11preset state, 8-2Rrack mount flange kit withhandle

Strona 203

1-218719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-18 2.4-mm Device Connector TypeNetwork Analyzer: 8722ES

Strona 204 - GOSUB SEQUENCE

iiiCertificationAgilent Technologies certifies that this product met its published specifications at the timeof shipment from the factory. Agilent Techno

Strona 205

1-228719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-19 2.4-mm Device Connector TypeNetwork Analyzer: 8722ES

Strona 206

1-238719/20/22ES Specifications and CharacteristicsCorrected System Performance (8722ES)Table 1-20 Type-N Device Connector TypeNetwork Analyzer: 8722ES

Strona 207

1-248719/20/22ES Specifications and CharacteristicsInstrument SpecificationsInstrument SpecificationsUncorrected Port PerformanceTable1-213.5-mm Device C

Strona 208

1-258719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable1-222.4-mm Device Connector Type8722ES (2.4-mm, 50Ω)Description Charact

Strona 209

1-268719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTest Port OutputTable 1-23 Test Port Output8719ES/20ES/22ES Test Port Output

Strona 210 - PHASE LOCK FAILURE

1-278719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-24 Test Port Output8719ES/20ES/22ES Test Port OutputDescription Spec

Strona 211

1-288719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-25 Test Port Output8719ES/20ES Test Port OutputDescription Specificat

Strona 212

1-298719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-26 Test Port Output8722ES Test Port OutputDescription Specification S

Strona 213

1-308719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-27 Test Port Output8719ES/20ES Test Port OutputDescription Specificat

Strona 214

1-318719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-28 Test Port Output8722ES Test Port OutputDescription Specification S

Strona 215

ivHow to Use This GuideThis guide uses the following conventions:This represents a key physically located on theinstrument.This represents a “softkey,

Strona 216

1-328719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-29 Test Port Output8719ES/20ES/22ES Test Port OutputDescription Spec

Strona 217

1-338719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTest Port InputTable 1-30 Test Port Input8719ES/20ES/22ES Test Port InputDes

Strona 218

1-348719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-31 Test Port Input8719ES/20ES/22ES Test Port InputDescription Specifi

Strona 219

1-358719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-32 Test Port Input8719/20/22ES Test Port InputDescription Supplement

Strona 220

1-368719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-34 Test Port Input8719/20ES Test Port InputDynamic Accuracy (Charact

Strona 221

1-378719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-34 Test Port Input8719/20ES Test Port Input

Strona 222

1-388719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-35 Test Port Input8722ES Test Port InputDynamic Accuracy (Characteri

Strona 223

1-398719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-35 Test Port Input8722ES Test Port Input

Strona 224 - 7 Options and Accessories

1-408719/20/22ES Specifications and CharacteristicsInstrument SpecificationsGeneral InformationTable 1-36 General Information8719/20/22ES General Inform

Strona 225 - Using This Chapter

1-418719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-37 General Information8719/20/22ES General InformationDescription Sp

Strona 226 - Analyzer Options Available

vDocumentation MapThe Installation and Quick Start Guide provides procedures forinstalling, configuring, and verifying the operation of the analyzer. I

Strona 227 - Service and Support Options

1-428719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-38 General Information8719/20/22ES General InformationDescription Su

Strona 228 - Accessories Available

1-438719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-39 General Information8719/20/22ES General InformationDescription Sp

Strona 229 - Options and Accessories

1-448719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-40 General Information8719/20/22ES General InformationDescription Sp

Strona 230

1-458719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-41 General Information8719/20/22ES General InformationDescription Sp

Strona 231

1-468719/20/22ES Specifications and CharacteristicsInstrument SpecificationsSpeed ParametersTable1-428719/20/22ES Measurement and Data Transfer Speed Pe

Strona 232

1-478719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-43 8719/20/22ES Recall and Sweep Speed PerformanceOperations Channel

Strona 233

1-488719/20/22ES Specifications and CharacteristicsInstrument SpecificationsTable 1-44 Sweep Time vs. IF BandwidthIF BandwidthTypical Sweep Time (second

Strona 234 - Test Configuration Accessories

1-498719/20/22ES Specifications and CharacteristicsInstrument SpecificationsPower Meter Calibration AccuracyTable 1-46 Power Meter Calibration Sweep Spe

Strona 235 - Keyboard Template

2-12 8719/20/22ETSpecifications and Characteristics

Strona 236

2-28719/20/22ET Specifications and CharacteristicsDefinitionsDefinitionsAll specifications and characteristics apply over a 23 °C ±3 °C range (unless othe

Strona 237 - Preset State

Contentsvii1. 8719/20/22ES Specifications and CharacteristicsDefinitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 238 - Table 8-1 Preset Conditions

2-38719/20/22ET Specifications and CharacteristicsCorrected System Performance (8719/20ET)Corrected System Performance (8719/20ET)The specifications in

Strona 239

2-48719/20/22ET Specifications and CharacteristicsCorrected System Performance (8719/20ET)Table 2-3 3.5-mm (50 Ω) Device Connector TypeNetwork Analyzer

Strona 240 - 0 Degrees

2-58719/20/22ET Specifications and CharacteristicsCorrected System Performance (8719/20ET)Transmissiona Uncertainty: Enhanced Response Calibration (Spe

Strona 241

2-68719/20/22ET Specifications and CharacteristicsCorrected System Performance (8719/20ET)This page is intentionally left blank.

Strona 242

2-78719/20/22ET Specifications and CharacteristicsCorrected System Performance (8722ET)Corrected System Performance (8722ET)The specifications in this s

Strona 243

2-88719/20/22ET Specifications and CharacteristicsCorrected System Performance (8722ET)Table 2-4 2.4-mm (50 Ω) Device Connector TypeNetwork Analyzer: 8

Strona 244

2-98719/20/22ET Specifications and CharacteristicsCorrected System Performance (8722ET)Transmissiona Uncertainty: Enhanced Response Calibration (Specifi

Strona 245

2-108719/20/22ET Specifications and CharacteristicsInstrument SpecificationsInstrument SpecificationsUncorrected Port PerformanceTable2-53.5-mm (50Ω) Dev

Strona 246 - Table 8-2 Preset Conditions

2-118719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable2-62.4-mm (50Ω) Device Connector Type8722ET (2.4-mm, 50Ω)DescriptionSpe

Strona 247

2-128719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTest Port OutputTable 2-7 Test Port Output8719ET/20ET/22ET Test Port OutputD

Strona 248 - Memory Allocation

ContentsviiiOption 089, Frequency Offset Mode (ES Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4Option 400, Four-Sampl

Strona 249

2-138719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-8 Test Port Output8719ET/20ET/22ET Test Port OutputDescription Speci

Strona 250

2-148719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-9 Test Port Output8719ES/20ET Test Port OutputDescription Specificati

Strona 251

2-158719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-10 Test Port Output8722ET Test Port OutputDescription Specification S

Strona 252 - Storing Data to Disk

2-168719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-11 Test Port Output8719ET/20ET Test Port OutputDescription Specificat

Strona 253

2-178719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-12 Test Port Output8722ET Test Port OutputDescription Specification S

Strona 254 - Using Saved Calibration Sets

2-188719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTest Port InputTable 2-13 Test Port Input8719ET/20ET/22ET Test Port InputDes

Strona 255

2-198719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-14 Test Port Input8719/20/22ET Test Port InputDescriptionSupplementa

Strona 256

2-208719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-16 Test Port Input8719/20ET Test Port Input (Transmission)Dynamic Ac

Strona 257 - The CITIfile Data Format

2-218719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-16 Test Port Input8719/20ET Test Port Input (Transmission)

Strona 258

2-228719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-17 Test Port Input8719/20ET Test Port Input (Reflection)Dynamic Accur

Strona 259 - CITIfile Examples

Contentsix10. Determining System Measurement UncertaintiesIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 260

2-238719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-17 Test Port Input8719/20ET Test Port Input (Reflection)

Strona 261

2-248719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-18 Test Port Input8722ET Test Port Input (Transmission)Dynamic Accur

Strona 262 - CITIfile Keywords

2-258719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-18 Test Port Input8722ET Test Port Input (Transmission)

Strona 263

2-268719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-19 Test Port Input8722ET Test Port Input (Reflection)Dynamic Accuracy

Strona 264

2-278719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-19 Test Port Input8722ET Test Port Input (Reflection)

Strona 265 - Useful Calculations

2-288719/20/22ET Specifications and CharacteristicsInstrument SpecificationsGeneral InformationTable 2-20 General Information8719/20/22ET General Inform

Strona 266

2-298719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-21 General Information8719/20/22ET General InformationDescription Sp

Strona 267

2-308719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-22 General Information8719/20/22ET General InformationDescription Su

Strona 268 - Uncertainties

2-318719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-23 General Information8719/20/22ET General InformationDescription Sp

Strona 269 - Introduction

2-328719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-24 General Information8719/20/22ET General InformationDescription Sp

Strona 270 - Sources of Measurement Errors

1-11 8719/20/22ESSpecifications and Characteristics

Strona 271 - Sources of Random Errors

2-338719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-25 General Information8719/20/22ET General InformationDescription Sp

Strona 272

2-348719/20/22ET Specifications and CharacteristicsInstrument SpecificationsSpeed ParametersTable2-268719/20/22ET Measurement and Data Transfer Speed Pe

Strona 273 - (−60/20)

2-358719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-27 8719/20/22ET Recall and Sweep Speed PerformanceOperations Channel

Strona 274 - (0.013/40)

2-368719/20/22ET Specifications and CharacteristicsInstrument SpecificationsTable 2-28 Sweep Time vs. IF BandwidthIF BandwidthTypical Sweep Time (second

Strona 275 - Forward Reflection Uncertainty

2-378719/20/22ET Specifications and CharacteristicsInstrument SpecificationsPower Meter Calibration AccuracyTable 2-30 Power Meter Calibration Sweep Spe

Strona 276

3-13 Front/Rear Panel

Strona 277 - Reverse Reflection Uncertainty

3-2Front/Rear PanelFront Panel FeaturesFront Panel FeaturesCAUTION Do not mistake the line switch for the disk eject button. See the followingillustra

Strona 278

3-3Front/Rear PanelFront Panel FeaturesFigure 3-2 8719/20/22ET Front PanelThe location of the following front panel features and key function blocks i

Strona 279

3-4Front/Rear PanelFront Panel Features9. The ENTRY block. This block includes the knob, the stepkeys, the number pad, and the backspace key. These al

Strona 280

3-5Front/Rear PanelAnalyzer DisplayAnalyzer DisplayFigure 3-3 Analyzer Display (Single Channel, Cartesian Format)The analyzer display shows various me

Komentarze do niniejszej Instrukcji

Brak uwag