Epson C82372 Instrukcja Obsługi Strona 267

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 266
EPSON Stylus Pro 10000/10000CF Revision B
Adjustment
S
elf-Diagnostics
2
67
5.3.8.2 PF Motor
Perform the PF motor reliability test.
The motor is actuated designated number.
When the reliability number is [-1], reliability is repeated until key is input.
When the reliability number is [-1], the biggest count number is 99,999,999 times (within 8
column), and the count become 0 in the case that this is exceeded.
Following figure showing the PF motor reliability test menu sequence.
Figure 5-99.
o
The maximum value of the paper feed is [100.0mm].
o The maximum value of the reliability number designation is [99,999,999 times].
o When the [Pause] key is pushed during the reliability test, the test can be broken.
Table 5-22.
Movement distance is less
than 8.6mm
Movement distanceis more
than 8.6mm
Speed 25 CPS 52 CPS
Acceleration speed 0.1G 0.2G
Decrease speed 0.1G 0.2G
Enter
Enter
Enter
FeedAmount:0.1mm
LifeCount:-1
Count :10
End : 50
Adjustable with "Paper Feed +/-" key
at unit of 0.1mm.
Adjustable with "Paper Feed +/-" key.
Przeglądanie stron 266
1 2 ... 262 263 264 265 266 267 268 269 270 271 272 ... 322 323

Komentarze do niniejszej Instrukcji

Brak uwag